 "format": "AJ Collector report",
 "version": "1.0",
 "meta": {
  "collectedUtc": "2026-11-13T07:30:00.0000000Z",
  "collectedLocal": "2026-11-13 11:30:00",
  "computer": "SCADA-SRV01",
  "user": "S13\\eng.admin",
  "isAdmin": true,
  "psVersion": "5.1.17763.6414",
  "days": 7,
  "durationS": 41.6
 },
 "system": {
  "os": "Microsoft Windows Server 2019 Standard",
  "version": "10.0.17763",
  "build": "17763",
  "installDate": "2023-03-14T09:00:00.0000000Z",
  "lastBoot": "2026-11-06T05:00:12.0000000Z",
  "uptimeHours": 170.5,
  "manufacturer": "Dell Inc.",
  "model": "PowerEdge R650",
  "partOfDomain": true,
  "domain": "s13.local",
  "cpu": "Intel(R) Xeon(R) Silver 4310 CPU @ 2.10GHz",
  "cores": 12,
  "logical": 24,
  "ramGB": 32,
  "ramFreeGB": 3.1,
  "timeZone": "Arabian Standard Time",
  "pendingReboot": [
   "Windows Update"
  ],
  "hotfixes": [
   {
    "id": "KB5034127",
    "description": "Security Update",
    "installedOn": "2026-02-11T00:00:00.0000000Z"
   },
   {
    "id": "KB5036896",
    "description": "Security Update",
    "installedOn": "2026-04-09T00:00:00.0000000Z"
   },
   {
    "id": "KB5037765",
    "description": "Security Update",
    "installedOn": "2026-05-14T00:00:00.0000000Z"
   }
  ]
 },
 "disks": [
  {
   "name": "C:",
   "label": "System",
   "fs": "NTFS",
   "sizeGB": 120,
   "freeGB": 9.5
  },
  {
   "name": "D:",
   "label": "Data",
   "fs": "NTFS",
   "sizeGB": 900,
   "freeGB": 312.4
  }
 ],
 "physicalDisks": [
  {
   "name": "PERC H755 SAS RAID",
   "mediaType": "SSD",
   "health": "Healthy",
   "status": "OK",
   "sizeGB": 1024
  }
 ],
 "services": [
  {
   "name": "W32Time",
   "display": "Windows Time",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "NT AUTHORITY\\LocalService",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "ScadaServer",
   "display": "SCADA Server",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "S13\\svc_scada",
   "path": "\"C:\\Program Files\\SCADA\\scadasrv.exe\"",
   "dependsOn": [
    "MSSQLSERVER",
    "LicenseServer"
   ],
   "dependents": []
  },
  {
   "name": "HistorianSvc",
   "display": "Historian Service",
   "state": "Stopped",
   "startMode": "Auto",
   "delayed": true,
   "account": "S13\\svc_hist",
   "path": "\"C:\\Program Files\\SCADA\\historian.exe\"",
   "dependsOn": [
    "MSSQLSERVER"
   ],
   "dependents": []
  },
  {
   "name": "OpcUaServer",
   "display": "OPC UA Server",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "LocalSystem",
   "path": "\"C:\\Program Files\\SCADA\\opcua.exe\"",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "LicenseServer",
   "display": "SCADA Licence Server",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "LocalSystem",
   "path": "",
   "dependsOn": [],
   "dependents": [
    "ScadaServer"
   ]
  },
  {
   "name": "MSSQLSERVER",
   "display": "SQL Server (MSSQLSERVER)",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "NT Service\\MSSQLSERVER",
   "path": "",
   "dependsOn": [],
   "dependents": [
    "ScadaServer",
    "HistorianSvc"
   ]
  },
  {
   "name": "sppsvc",
   "display": "Software Protection",
   "state": "Stopped",
   "startMode": "Auto",
   "delayed": true,
   "account": "NT AUTHORITY\\NetworkService",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "gupdate",
   "display": "Google Update Service (gupdate)",
   "state": "Stopped",
   "startMode": "Auto",
   "delayed": true,
   "account": "LocalSystem",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "Spooler",
   "display": "Print Spooler",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "LocalSystem",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "TermService",
   "display": "Remote Desktop Services",
   "state": "Running",
   "startMode": "Manual",
   "delayed": false,
   "account": "NT Authority\\NetworkService",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "WinRM",
   "display": "Windows Remote Management (WS-Management)",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "NT AUTHORITY\\NetworkService",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "MpsSvc",
   "display": "Windows Defender Firewall",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "NT Authority\\LocalService",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "WinDefend",
   "display": "Microsoft Defender Antivirus Service",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "LocalSystem",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "Netlogon",
   "display": "Netlogon",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "LocalSystem",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "Dnscache",
   "display": "DNS Client",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "NT AUTHORITY\\NetworkService",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "SNMP",
   "display": "SNMP Service",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "LocalSystem",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "RemoteSupportAgent",
   "display": "Remote Support Agent",
   "state": "Running",
   "startMode": "Auto",
   "delayed": false,
   "account": "LocalSystem",
   "path": "C:\\Program Files\\RSA\\rsagent.exe",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "RemoteRegistry",
   "display": "Remote Registry",
   "state": "Stopped",
   "startMode": "Manual",
   "delayed": false,
   "account": "NT AUTHORITY\\LocalService",
   "path": "",
   "dependsOn": [],
   "dependents": []
  },
  {
   "name": "BITS",
   "display": "Background Intelligent Transfer Service",
   "state": "Running",
   "startMode": "Manual",
   "delayed": false,
   "account": "LocalSystem",
   "path": "",
   "dependsOn": [],
   "dependents": []
  }
 ],
 "events": [
  {
   "log": "System",
   "time": "2026-11-12T01:10:05.0000000Z",
   "id": 7031,
   "source": "Service Control Manager",
   "level": "Error",
   "message": "The Historian Service service terminated unexpectedly. It has done this 1 time(s). The following corrective action will be taken in 60000 milliseconds: Restart the service."
  },
  {
   "log": "System",
   "time": "2026-11-12T02:11:05.0000000Z",
   "id": 7031,
   "source": "Service Control Manager",
   "level": "Error",
   "message": "The Historian Service service terminated unexpectedly. It has done this 2 time(s). The following corrective action will be taken in 60000 milliseconds: Restart the service."
  },
  {
   "log": "System",
   "time": "2026-11-12T03:12:05.0000000Z",
   "id": 7031,
   "source": "Service Control Manager",
   "level": "Error",
   "message": "The Historian Service service terminated unexpectedly. It has done this 3 time(s). The following corrective action will be taken in 60000 milliseconds: Restart the service."
  },
  {
   "log": "System",
   "time": "2026-11-11T04:13:05.0000000Z",
   "id": 7031,
   "source": "Service Control Manager",
   "level": "Error",
   "message": "The Historian Service service terminated unexpectedly. It has done this 4 time(s). The following corrective action will be taken in 60000 milliseconds: Restart the service."
  },
  {
   "log": "System",
   "time": "2026-11-11T05:14:05.0000000Z",
   "id": 7031,
   "source": "Service Control Manager",
   "level": "Error",
   "message": "The Historian Service service terminated unexpectedly. It has done this 5 time(s). The following corrective action will be taken in 60000 milliseconds: Restart the service."
  },
  {
   "log": "Application",
   "time": "2026-11-12T01:10:03.0000000Z",
   "id": 1000,
   "source": "Application Error",
   "level": "Error",
   "message": "Faulting application name: historian.exe, version: 7.2.1.0, Faulting module name: ntdll.dll, Exception code: 0xc0000374"
  },
  {
   "log": "Application",
   "time": "2026-11-12T02:11:03.0000000Z",
   "id": 1000,
   "source": "Application Error",
   "level": "Error",
   "message": "Faulting application name: historian.exe, version: 7.2.1.0, Faulting module name: ntdll.dll, Exception code: 0xc0000374"
  },
  {
   "log": "Application",
   "time": "2026-11-12T03:12:03.0000000Z",
   "id": 1000,
   "source": "Application Error",
   "level": "Error",
   "message": "Faulting application name: historian.exe, version: 7.2.1.0, Faulting module name: ntdll.dll, Exception code: 0xc0000374"
  },
  {
   "log": "Application",
   "time": "2026-11-11T04:13:03.0000000Z",
   "id": 1000,
   "source": "Application Error",
   "level": "Error",
   "message": "Faulting application name: historian.exe, version: 7.2.1.0, Faulting module name: ntdll.dll, Exception code: 0xc0000374"
  },
  {
   "log": "Application",
   "time": "2026-11-11T05:14:03.0000000Z",
   "id": 1000,
   "source": "Application Error",
   "level": "Error",
   "message": "Faulting application name: historian.exe, version: 7.2.1.0, Faulting module name: ntdll.dll, Exception code: 0xc0000374"
  },
  {
   "log": "System",
   "time": "2026-11-06T05:02:11.0000000Z",
   "id": 1129,
   "source": "Microsoft-Windows-GroupPolicy",
   "level": "Error",
   "message": "The processing of Group Policy failed because of lack of network connectivity to a domain controller."
  },
  {
   "log": "System",
   "time": "2026-10-02T04:58:40.0000000Z",
   "id": 1129,
   "source": "Microsoft-Windows-GroupPolicy",
   "level": "Error",
   "message": "The processing of Group Policy failed because of lack of network connectivity to a domain controller."
  },
  {
   "log": "System",
   "time": "2026-10-02T05:06:02.0000000Z",
   "id": 1129,
   "source": "Microsoft-Windows-GroupPolicy",
   "level": "Error",
   "message": "The processing of Group Policy failed because of lack of network connectivity to a domain controller."
  },
  {
   "log": "System",
   "time": "2026-10-02T04:58:12.0000000Z",
   "id": 5719,
   "source": "NETLOGON",
   "level": "Error",
   "message": "This computer was not able to set up a secure session with a domain controller in domain S13 due to the following: There are currently no logon servers available to service the logon request."
  },
  {
   "log": "System",
   "time": "2026-11-06T05:01:50.0000000Z",
   "id": 5719,
   "source": "NETLOGON",
   "level": "Error",
   "message": "This computer was not able to set up a secure session with a domain controller in domain S13 due to the following: There are currently no logon servers available to service the logon request."
  },
  {
   "log": "System",
   "time": "2026-11-08T22:40:00.0000000Z",
   "id": 153,
   "source": "disk",
   "level": "Warning",
   "message": "The IO operation at logical block address 0x2a1f8 for Disk 0 (PDO name: \\Device\\00000034) was retried."
  },
  {
   "log": "System",
   "time": "2026-11-09T22:41:00.0000000Z",
   "id": 153,
   "source": "disk",
   "level": "Warning",
   "message": "The IO operation at logical block address 0x2a1f8 for Disk 0 (PDO name: \\Device\\00000034) was retried."
  },
  {
   "log": "System",
   "time": "2026-11-010T22:42:00.0000000Z",
   "id": 153,
   "source": "disk",
   "level": "Warning",
   "message": "The IO operation at logical block address 0x2a1f8 for Disk 0 (PDO name: \\Device\\00000034) was retried."
  },
  {
   "log": "System",
   "time": "2026-11-011T22:43:00.0000000Z",
   "id": 153,
   "source": "disk",
   "level": "Warning",
   "message": "The IO operation at logical block address 0x2a1f8 for Disk 0 (PDO name: \\Device\\00000034) was retried."
  },
  {
   "log": "System",
   "time": "2026-11-09T07:15:22.0000000Z",
   "id": 4199,
   "source": "Tcpip",
   "level": "Error",
   "message": "The system detected an address conflict for IP address 10.13.0.20 with the system having network hardware address 02-AA-00-00-09-09. Network operations on this system may be disrupted as a result."
  },
  {
   "log": "System",
   "time": "2026-11-10T10:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-11T11:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-12T12:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-10T13:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-11T14:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-12T15:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-10T16:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-11T17:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-12T18:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-10T19:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-11T10:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-12T11:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-10T12:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-11T13:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-12T14:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-10T15:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-11T16:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-12T17:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-10T18:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-11T19:00:00.0000000Z",
   "id": 10016,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Warning",
   "message": "The application-specific permission settings do not grant Local Activation permission for the COM Server application with CLSID {D63B10C5-BB46-4990-A94F-E40B9D520160}"
  },
  {
   "log": "System",
   "time": "2026-11-10T00:30:00.0000000Z",
   "id": 10009,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Error",
   "message": "DCOM was unable to communicate with the computer ENG-WS02 using any of the configured protocols; requested by PID 1d4c (C:\\Program Files\\SCADA\\opcbridge.exe)."
  },
  {
   "log": "System",
   "time": "2026-11-11T01:30:00.0000000Z",
   "id": 10009,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Error",
   "message": "DCOM was unable to communicate with the computer ENG-WS02 using any of the configured protocols; requested by PID 1d4c (C:\\Program Files\\SCADA\\opcbridge.exe)."
  },
  {
   "log": "System",
   "time": "2026-11-12T02:30:00.0000000Z",
   "id": 10009,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Error",
   "message": "DCOM was unable to communicate with the computer ENG-WS02 using any of the configured protocols; requested by PID 1d4c (C:\\Program Files\\SCADA\\opcbridge.exe)."
  },
  {
   "log": "System",
   "time": "2026-11-10T03:30:00.0000000Z",
   "id": 10009,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Error",
   "message": "DCOM was unable to communicate with the computer ENG-WS02 using any of the configured protocols; requested by PID 1d4c (C:\\Program Files\\SCADA\\opcbridge.exe)."
  },
  {
   "log": "System",
   "time": "2026-11-11T04:30:00.0000000Z",
   "id": 10009,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Error",
   "message": "DCOM was unable to communicate with the computer ENG-WS02 using any of the configured protocols; requested by PID 1d4c (C:\\Program Files\\SCADA\\opcbridge.exe)."
  },
  {
   "log": "System",
   "time": "2026-11-12T05:30:00.0000000Z",
   "id": 10009,
   "source": "Microsoft-Windows-DistributedCOM",
   "level": "Error",
   "message": "DCOM was unable to communicate with the computer ENG-WS02 using any of the configured protocols; requested by PID 1d4c (C:\\Program Files\\SCADA\\opcbridge.exe)."
  },
  {
   "log": "System",
   "time": "2026-11-06T04:59:58.0000000Z",
   "id": 41,
   "source": "Microsoft-Windows-Kernel-Power",
   "level": "Critical",
   "message": "The system has rebooted without cleanly shutting down first. This error could be caused if the system stopped responding, crashed, or lost power unexpectedly."
  },
  {
   "log": "System",
   "time": "2026-11-06T05:00:40.0000000Z",
   "id": 6008,
   "source": "EventLog",
   "level": "Error",
   "message": "The previous system shutdown at 08:58:31 on 06/11/2026 was unexpected."
  },
  {
   "log": "System",
   "time": "2026-11-06T05:00:41.0000000Z",
   "id": 6005,
   "source": "EventLog",
   "level": "Information",
   "message": "The Event log service was started."
  },
  {
   "log": "System",
   "time": "2026-11-10T03:00:02.0000000Z",
   "id": 1,
   "source": "Microsoft-Windows-Kernel-General",
   "level": "Information",
   "message": "The system time has changed to 2026-11-10T03:00:02.512Z from 2026-11-10T03:00:04.391Z. Change Reason: System time synchronized with the hardware clock."
  },
  {
   "log": "System",
   "time": "2026-11-12T11:20:00.0000000Z",
   "id": 36,
   "source": "Microsoft-Windows-Time-Service",
   "level": "Warning",
   "message": "The time service has not synchronized the system time for 86400 seconds because none of the time service providers provided a usable time stamp."
  },
  {
   "log": "System",
   "time": "2026-11-04T10:12:00.0000000Z",
   "id": 7045,
   "source": "Service Control Manager",
   "level": "Information",
   "message": "A service was installed in the system. Service Name: RemoteSupportAgent Service File Name: C:\\Program Files\\RSA\\rsagent.exe Service Type: user mode service Service Start Type: auto start Service Account: LocalSystem"
  },
  {
   "log": "Security",
   "time": "2026-11-10T00:00:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-11T01:01:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-12T02:02:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-10T03:03:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-11T04:04:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-12T05:05:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-10T06:00:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-11T07:01:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-12T08:02:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-10T09:03:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-11T00:04:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-12T01:05:00.0000000Z",
   "id": 4625,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "An account failed to log on. Account Name: scada_op Failure Reason: Unknown user name or bad password. Status: 0xC000006D Sub Status: 0xC000006A"
  },
  {
   "log": "Security",
   "time": "2026-11-12T09:41:00.0000000Z",
   "id": 4740,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "A user account was locked out. Account Name: scada_op Caller Computer Name: HMI-02"
  },
  {
   "log": "Security",
   "time": "2026-11-04T10:13:00.0000000Z",
   "id": 4732,
   "source": "Microsoft-Windows-Security-Auditing",
   "level": "Information",
   "message": "A member was added to a security-enabled local group. Member: S13\\vendor.support Group: Administrators"
  },
  {
   "log": "Diagnostics-Performance",
   "time": "2026-11-06T05:04:10.0000000Z",
   "id": 100,
   "source": "Microsoft-Windows-Diagnostics-Performance",
   "level": "Critical",
   "message": "Windows has started up: Boot Duration : 184523ms IsDegradation : false Incident Time (UTC) : 11/6/2026 5:00:40 AM"
  },
  {
   "log": "Diagnostics-Performance",
   "time": "2026-10-02T05:07:00.0000000Z",
   "id": 100,
   "source": "Microsoft-Windows-Diagnostics-Performance",
   "level": "Error",
   "message": "Windows has started up: Boot Duration : 152210ms IsDegradation : false"
  }
 ],
 "time": {
  "status": "Leap Indicator: 0(no warning)\nStratum: 4 (secondary reference - syncd by (S)NTP)\nPrecision: -23 (119.209ns per tick)\nRoot Delay: 0.0468750s\nRoot Dispersion: 0.5313000s\nReferenceId: 0x0A0D0005 (source IP:  10.13.0.5)\nLast Successful Sync Time: 11/11/2026 11:20:00 AM\nSource: DC01.s13.local\nPoll Interval: 10 (1024s)\n",
  "configuration": "[TimeProviders]\nNtpClient (Local)\nEnabled: 1 (Local)\nType: NT5DS (Local)\n",
  "source": "DC01.s13.local",
  "timeZone": "Arabian Standard Time"
 },
 "network": {
  "ipconfig": "Windows IP Configuration\n\n   Host Name . . . . . . . . . . . . : SCADA-SRV01\n   Primary Dns Suffix  . . . . . . . : s13.local\n\nEthernet adapter SCADA LAN:\n\n   Description . . . . . . . . . . . : Intel(R) Ethernet Server Adapter I350\n   Physical Address. . . . . . . . . : 00-1B-21-AA-10-20\n   DHCP Enabled. . . . . . . . . . . : No\n   IPv4 Address. . . . . . . . . . . : 10.13.0.20(Preferred)\n   Subnet Mask . . . . . . . . . . . : 255.255.255.128\n   Default Gateway . . . . . . . . . : 10.13.0.1\n   DNS Servers . . . . . . . . . . . : 10.13.0.5\n\nEthernet adapter Corporate:\n\n   Description . . . . . . . . . . . : Intel(R) Ethernet Server Adapter I350 #2\n   Physical Address. . . . . . . . . : 00-1B-21-AA-10-21\n   DHCP Enabled. . . . . . . . . . . : No\n   IPv4 Address. . . . . . . . . . . : 172.20.4.15(Preferred)\n   Subnet Mask . . . . . . . . . . . : 255.255.255.0\n   Default Gateway . . . . . . . . . : 172.20.4.1\n",
  "route": "IPv4 Route Table\n===========================================================================\nActive Routes:\nNetwork Destination        Netmask          Gateway       Interface  Metric\n          0.0.0.0          0.0.0.0        10.13.0.1       10.13.0.20     25\n          0.0.0.0          0.0.0.0       172.20.4.1      172.20.4.15     25\n        10.13.0.0  255.255.255.128         On-link        10.13.0.20    281\n       172.20.4.0    255.255.255.0         On-link       172.20.4.15    281\n===========================================================================\n",
  "arp": "\nInterface: 10.13.0.20 --- 0x6\n  Internet Address      Physical Address      Type\n  10.13.0.1             00-1b-1b-aa-00-01     dynamic\n  10.13.0.14            02-aa-00-00-02-01     dynamic\n",
  "netstat": "\n  Proto  Local Address          Foreign Address        State           PID\n  TCP    0.0.0.0:135            0.0.0.0:0              LISTENING       912\n  TCP    0.0.0.0:445            0.0.0.0:0              LISTENING       4\n  TCP    0.0.0.0:1433           0.0.0.0:0              LISTENING       3120\n  TCP    0.0.0.0:2404           0.0.0.0:0              LISTENING       4410\n  TCP    0.0.0.0:3389           0.0.0.0:0              LISTENING       1180\n  TCP    0.0.0.0:4840           0.0.0.0:0              LISTENING       4620\n  TCP    0.0.0.0:5985           0.0.0.0:0              LISTENING       4\n  TCP    10.13.0.20:52044       10.13.0.14:102         ESTABLISHED     4410\n  TCP    10.13.0.20:52051       10.13.0.17:102         SYN_SENT        4410\n",
  "adapters": [
   {
    "name": "SCADA LAN",
    "description": "Intel(R) Ethernet Server Adapter I350",
    "status": "Up",
    "linkSpeed": "1 Gbps",
    "mac": "00-1B-21-AA-10-20"
   },
   {
    "name": "Corporate",
    "description": "Intel(R) Ethernet Server Adapter I350 #2",
    "status": "Up",
    "linkSpeed": "1 Gbps",
    "mac": "00-1B-21-AA-10-21"
   }
  ]
 },
 "listening": [
  {
   "proto": "TCP",
   "address": "0.0.0.0",
   "port": 135,
   "pid": 912,
   "process": "svchost"
  },
  {
   "proto": "TCP",
   "address": "0.0.0.0",
   "port": 445,
   "pid": 4,
   "process": "System"
  },
  {
   "proto": "TCP",
   "address": "0.0.0.0",
   "port": 1433,
   "pid": 3120,
   "process": "sqlservr"
  },
  {
   "proto": "TCP",
   "address": "0.0.0.0",
   "port": 2404,
   "pid": 4410,
   "process": "scadasrv"
  },
  {
   "proto": "TCP",
   "address": "0.0.0.0",
   "port": 3389,
   "pid": 1180,
   "process": "svchost"
  },
  {
   "proto": "TCP",
   "address": "0.0.0.0",
   "port": 4840,
   "pid": 4620,
   "process": "opcua"
  },
  {
   "proto": "TCP",
   "address": "0.0.0.0",
   "port": 5985,
   "pid": 4,
   "process": "System"
  },
  {
   "proto": "TCP",
   "address": "0.0.0.0",
   "port": 5938,
   "pid": 5100,
   "process": "rsagent"
  },
  {
   "proto": "UDP",
   "address": "0.0.0.0",
   "port": 123,
   "pid": 1300,
   "process": "svchost"
  },
  {
   "proto": "UDP",
   "address": "0.0.0.0",
   "port": 161,
   "pid": 2200,
   "process": "snmp"
  }
 ],
 "processes": [
  {
   "name": "sqlservr",
   "pid": 3120,
   "cpuS": 182340.2,
   "workingSetMB": 12480,
   "privateMB": 13010,
   "path": "C:\\Program Files\\Microsoft SQL Server\\MSSQL15.MSSQLSERVER\\MSSQL\\Binn\\sqlservr.exe"
  },
  {
   "name": "scadasrv",
   "pid": 4410,
   "cpuS": 96211.5,
   "workingSetMB": 2210,
   "privateMB": 2480,
   "path": "C:\\Program Files\\SCADA\\scadasrv.exe"
  },
  {
   "name": "MsMpEng",
   "pid": 3400,
   "cpuS": 40211.0,
   "workingSetMB": 380,
   "privateMB": 410,
   "path": null
  },
  {
   "name": "rsagent",
   "pid": 5100,
   "cpuS": 120.3,
   "workingSetMB": 45,
   "privateMB": 38,
   "path": "C:\\Program Files\\RSA\\rsagent.exe"
  }
 ],
 "firewall": {
  "profiles": [
   {
    "name": "Domain",
    "enabled": "True",
    "inbound": "Block",
    "outbound": "Allow"
   },
   {
    "name": "Private",
    "enabled": "True",
    "inbound": "Block",
    "outbound": "Allow"
   },
   {
    "name": "Public",
    "enabled": "False",
    "inbound": "NotConfigured",
    "outbound": "NotConfigured"
   }
  ],
  "rules": [
   {
    "name": "RemoteDesktop-UserMode-In-TCP",
    "display": "Remote Desktop - User Mode (TCP-In)",
    "group": "Remote Desktop",
    "direction": "Inbound",
    "action": "Allow",
    "profile": "Domain, Private, Public",
    "protocol": "TCP",
    "localPort": "3389",
    "remoteAddress": "Any",
    "program": null
   },
   {
    "name": "SCADA-IEC104",
    "display": "SCADA IEC 60870-5-104 from control centre",
    "group": "",
    "direction": "Inbound",
    "action": "Allow",
    "profile": "Domain",
    "protocol": "TCP",
    "localPort": "2404",
    "remoteAddress": "10.10.0.0/16",
    "program": null
   },
   {
    "name": "SQL-1433",
    "display": "SQL Server",
    "group": "",
    "direction": "Inbound",
    "action": "Allow",
    "profile": "Domain, Private, Public",
    "protocol": "TCP",
    "localPort": "1433",
    "remoteAddress": "Any",
    "program": null
   },
   {
    "name": "OPCUA-4840",
    "display": "OPC UA Server",
    "group": "",
    "direction": "Inbound",
    "action": "Allow",
    "profile": "Domain",
    "protocol": "TCP",
    "localPort": "4840",
    "remoteAddress": "LocalSubnet",
    "program": null
   },
   {
    "name": "FPS-SMB-In-TCP",
    "display": "File and Printer Sharing (SMB-In)",
    "group": "File and Printer Sharing",
    "direction": "Inbound",
    "action": "Allow",
    "profile": "Domain, Private, Public",
    "protocol": "TCP",
    "localPort": "445",
    "remoteAddress": "Any",
    "program": null
   },
   {
    "name": "WINRM-HTTP-In-TCP",
    "display": "Windows Remote Management (HTTP-In)",
    "group": "Windows Remote Management",
    "direction": "Inbound",
    "action": "Allow",
    "profile": "Domain, Private, Public",
    "protocol": "TCP",
    "localPort": "5985",
    "remoteAddress": "Any",
    "program": null
   },
   {
    "name": "ENG-ALL",
    "display": "Allow all from engineering PC",
    "group": "",
    "direction": "Inbound",
    "action": "Allow",
    "profile": "Domain",
    "protocol": "Any",
    "localPort": "Any",
    "remoteAddress": "10.13.0.110",
    "program": null
   },
   {
    "name": "RSA-Agent",
    "display": "Remote Support Agent",
    "group": "",
    "direction": "Inbound",
    "action": "Allow",
    "profile": "Domain, Private, Public",
    "protocol": "Any",
    "localPort": "Any",
    "remoteAddress": "Any",
    "program": "C:\\Program Files\\RSA\\rsagent.exe"
   }
  ]
 },
 "accounts": {
  "users": [
   {
    "name": "Administrator",
    "enabled": true,
    "lastLogon": "2026-11-12T08:00:00.0000000Z",
    "passwordLastSet": "2023-03-14T09:30:00.0000000Z",
    "passwordExpires": null,
    "passwordRequired": true,
    "sid": "S-1-5-21-111-222-333-500",
    "description": "Built-in account for administering the computer/domain"
   },
   {
    "name": "Guest",
    "enabled": false,
    "lastLogon": null,
    "passwordLastSet": null,
    "passwordExpires": null,
    "passwordRequired": false,
    "sid": "S-1-5-21-111-222-333-501",
    "description": "Built-in account for guest access"
   },
   {
    "name": "scada_op",
    "enabled": true,
    "lastLogon": "2026-11-12T09:30:00.0000000Z",
    "passwordLastSet": "2024-01-10T08:00:00.0000000Z",
    "passwordExpires": null,
    "passwordRequired": true,
    "sid": "S-1-5-21-111-222-333-1001",
    "description": "Shared operator account"
   },
   {
    "name": "commissioning",
    "enabled": true,
    "lastLogon": "2025-12-02T10:00:00.0000000Z",
    "passwordLastSet": "2025-06-01T08:00:00.0000000Z",
    "passwordExpires": null,
    "passwordRequired": false,
    "sid": "S-1-5-21-111-222-333-1002",
    "description": "FAT account"
   }
  ],
  "admins": [
   {
    "name": "S13\\Domain Admins",
    "source": "ActiveDirectory",
    "class": "Group"
   },
   {
    "name": "SCADA-SRV01\\Administrator",
    "source": "Local",
    "class": "User"
   },
   {
    "name": "S13\\eng.admin",
    "source": "ActiveDirectory",
    "class": "User"
   },
   {
    "name": "S13\\vendor.support",
    "source": "ActiveDirectory",
    "class": "User"
   },
   {
    "name": "SCADA-SRV01\\scada_op",
    "source": "Local",
    "class": "User"
   }
  ],
  "rdpUsers": [
   {
    "name": "S13\\scada.operators",
    "source": "ActiveDirectory",
    "class": "Group"
   }
  ],
  "netAccounts": "Force user logoff how long after time expires?:       Never\nMinimum password age (days):                          0\nMaximum password age (days):                          Unlimited\nMinimum password length:                              6\nLength of password history maintained:                None\nLockout threshold:                                    Never\nLockout duration (minutes):                           30\nLockout observation window (minutes):                 30\nComputer role:                                        SERVER\nThe command completed successfully.\n"
 },
 "security": {
  "rdpDenied": 0,
  "nla": 0,
  "smb1": true,
  "enableLUA": 1,
  "usbStorStart": 3,
  "noDriveTypeAutoRun": null,
  "llmnrEnableMulticast": null,
  "defender": {
   "serviceEnabled": true,
   "antivirusEnabled": true,
   "realTime": true,
   "signaturesUpdated": "2026-10-20T03:00:00.0000000Z",
   "productVersion": "4.18.24090.11"
  },
  "auditpol": "System audit policy\nCategory/Subcategory                      Setting\nLogon/Logoff\n  Logon                                   Success and Failure\n  Account Lockout                         Success\nAccount Management\n  User Account Management                 Success\nPolicy Change\n  Audit Policy Change                     No Auditing\n"
 },
 "domain": {
  "partOfDomain": true,
  "name": "s13.local",
  "secureChannel": true,
  "scVerify": "Flags: b0 HAS_IP  HAS_TIMESERV\nTrusted DC Name \\\\DC01.s13.local\nTrusted DC Connection Status Status = 0 0x0 NERR_Success\nTrust Verification Status = 0 0x0 NERR_Success\nThe command completed successfully\n",
  "dsgetdc": "           DC: \\\\DC01.s13.local\n      Address: \\\\10.13.0.5\n     Dom Name: s13.local\nThe command completed successfully\n",
  "gpresult": "COMPUTER SETTINGS\n------------------\n    Last time Group Policy was applied: 11/13/2026 at 11:02:10 AM\n    Group Policy was applied from:      DC01.s13.local\n"
 },
 "software": [
  {
   "name": "SCADA Server",
   "version": "7.2.1",
   "publisher": "SCADA Vendor",
   "installDate": "20230320"
  },
  {
   "name": "Microsoft SQL Server 2019 (64-bit)",
   "version": "15.0.2000.5",
   "publisher": "Microsoft Corporation",
   "installDate": "20230315"
  },
  {
   "name": "Remote Support Agent",
   "version": "3.4",
   "publisher": "RSA Tools",
   "installDate": "20261104"
  },
  {
   "name": "Google Chrome",
   "version": "118.0.5993.89",
   "publisher": "Google LLC",
   "installDate": "20231020"
  },
  {
   "name": "7-Zip 23.01 (x64)",
   "version": "23.01",
   "publisher": "Igor Pavlov",
   "installDate": "20240105"
  }
 ],
 "certificates": [
  {
   "store": "My",
   "subject": "CN=SCADA-SRV01.s13.local",
   "issuer": "CN=S13-ISSUING-CA, DC=s13, DC=local",
   "notBefore": "2025-11-28T00:00:00.0000000Z",
   "notAfter": "2026-11-28T00:00:00.0000000Z",
   "thumbprint": "5A1C9E0B7D33F2A64C18E2D90B6A7F1C2E3D4B5A",
   "hasPrivateKey": true,
   "sigAlg": "sha256RSA",
   "keySize": 2048,
   "eku": [
    "Server Authentication",
    "Client Authentication"
   ],
   "dns": [
    "SCADA-SRV01.s13.local"
   ]
  },
  {
   "store": "My",
   "subject": "CN=SCADA-SRV01 OPC UA Server, O=Sample Substation",
   "issuer": "CN=SCADA-SRV01 OPC UA Server, O=Sample Substation",
   "notBefore": "2025-03-01T00:00:00.0000000Z",
   "notAfter": "2030-03-01T00:00:00.0000000Z",
   "thumbprint": "4BA78D56541830393573F122010AA12D4117B782",
   "hasPrivateKey": true,
   "sigAlg": "sha256RSA",
   "keySize": 2048,
   "eku": [
    "Server Authentication",
    "Client Authentication"
   ],
   "dns": [
    "scada-srv01"
   ]
  },
  {
   "store": "My",
   "subject": "CN=SQL-OLD",
   "issuer": "CN=SQL-OLD",
   "notBefore": "2020-01-01T00:00:00.0000000Z",
   "notAfter": "2025-01-01T00:00:00.0000000Z",
   "thumbprint": "9F0E1D2C3B4A59687766554433221100FFEEDDCC",
   "hasPrivateKey": true,
   "sigAlg": "sha1RSA",
   "keySize": 1024,
   "eku": [
    "Server Authentication"
   ],
   "dns": []
  },
  {
   "store": "Remote Desktop",
   "subject": "CN=SCADA-SRV01.s13.local",
   "issuer": "CN=SCADA-SRV01.s13.local",
   "notBefore": "2026-04-02T00:00:00.0000000Z",
   "notAfter": "2027-04-02T00:00:00.0000000Z",
   "thumbprint": "1122334455667788990011223344556677889900",
   "hasPrivateKey": true,
   "sigAlg": "sha256RSA",
   "keySize": 2048,
   "eku": [
    "Server Authentication"
   ],
   "dns": [
    "SCADA-SRV01.s13.local"
   ]
  }
 ],
 "skipped": []
}